The Hi-Force ATDP series of twin double acting air driven hydrostatic pressure testing pumps offer a choice of 3 models with output pressure capacities ranging from 87 bar (1260 psi) to 1489 bar (21600 psi). The twin double acting design offers a much higher displacement volume per stroke than the smaller AHP & AHP2 series, making it ideal for prefill as well as pressure testing. All models are supplied with a 150 mm diameter glycerine filled vibra-gauge (calibrated on request), inlet airline filter, lubricator and regulator unit, pump start/stop valve and fluid strainer.
- Infinitely variable output pressure and fluid displacement speed
- Air consumption 212 scfm (6 m3 / minute) at 7 bar
- Optional stroke counter system, chart recorder and chemical duty distance piece available on request
- Airline regulator for easy setting of input air and output hydraulic pressure
- Fluid inlet port of 1¼" BSPF with integral Y-type fluid strainer
SPECIFICATIONS
MODEL NO. | MAX OUTPUT PRESSURE (BAR) AT AIRLINE INPUT PRESSURE | FLUID VOLUME DISPLACEMENT PER STROKE (CM3) | OUTLET PORT THREAD | WEIGHT KG | DIMENSIONS IN MM | ||||
---|---|---|---|---|---|---|---|---|---|
20 PSI 1.38 BAR | 60 PSI 4.14 BAR | 100 PSI 6.9 BAR | LENGTH | WIDTH | HEIGHT | ||||
ATDP63 | 87 | 260 | 434 | 275 | 1/2" NPT | 96 | 765 | 570 | 700 |
ATDP125 | 172 | 517 | 862 | 140 | 1/2" NPT | 96 | 765 | 570 | 700 |
ATDP216 | 298 | 894 | 1489 | 79 | 1 1/8"-12UNF | 96 | 765 | 570 | 700 |
OUTPUT FLOW RATE
HYDRAULIC PRESSURE | APPROXIMATE RATE OF DISCHARGE (LITRES/MIN) AT AIR INPUT PRESSURE 100 PSI (7BAR) | |||
---|---|---|---|---|
PSI | BAR | ATDP63 | ATDP125 | ATDP216 |
0 | 0 | 32.2 | 16.9 | 9.5 |
1000 | 69 | 25.7 | 14 | 8.8 |
2000 | 138 | 20.5 | 12.3 | 8 |
3000 | 207 | 16.2 | 10.6 | 7.4 |
4000 | 276 | 12.5 | 9.4 | 6.9 |
5000 | 345 | 8 | 8.3 | 6.4 |
6000 | 414 | 2.8 | 7.3 | 6.1 |
8000 | 552 | * | 4.8 | 5.5 |
10000 | 690 | * | 3 | 4.9 |
12000 | 828 | * | 0.4 | 4.3 |
16000 | 1103 | * | * | 3.2 |
20000 | 1379 | * | * | 1.6 |
Note: * Pressure exceeds pump capacity